Assessment of Quality of Drinking Water in Selected Areas of Badulla District: An Approach to Causative Factors for Chronic Kidney Disease of Unknown Etiology (CKDu)

Show simple item record

dc.contributor.author Rathnayake, R.M.M.L.
dc.contributor.author Purathini, M.
dc.contributor.author Henagamage, A.P.
dc.contributor.author Premetilake, M.M.S.N.
dc.date.accessioned 2019-04-09T08:08:28Z
dc.date.available 2019-04-09T08:08:28Z
dc.date.issued 2019-02
dc.identifier.isbn 9789550481255
dc.identifier.uri http://erepo.lib.uwu.ac.lk/bitstream/handle/123456789/206/169.pdf?sequence=1&isAllowed=y
dc.description.abstract Chronic Kidney Disease of unknown etiology (CKDu) is one of the major health issues in Sri Lanka. Though the main reason for the CKDu has not yet been identified, it is suggested that this is due to multi-factorial effect. However, it strongly correlates with certain drinking water quality parameters. Hence, this study was aimed on evaluating the quality of drinking water sources in CKDu potential areas in Badulla district and compare with the Sri Lanka Standard (SLS) water quality admissible levels. Drinking water samples were collected from dug wells in CKDu potential areas in Uva Province; Lower- Rathkinda, Ginnoruwa, Rideemaliyadda and Uva Paranagama (control area). Parameters such as pH, electrical conductivity, anions and heavy metals were analyzed following standard methods. Data were analyzed by one sample T- test, using IBM SPSS statistics 21.0 version. Mean values of pH value, electrical conductivity, chloride levels, nitrate levels and hardness of water samples of all the areas were within the acceptable range for portable water according to the standard SLS 614:2013. Mean fluoride contents and phosphate contents of all potential CKDu areas were less than the stipulated standard levels while Uva Paranagama exceeds the standard levels. Cadmium, as one of the most suspected causative heavy metal for CKDu, showed significantly higher level (P<0.05) than that of the admissible level of 0.003 mg L-1 in Lower- Rathkinda (0.005± 0.001 mg L-1) and Ginnoruwa (0.006± 0.001 mg L-1). Control area showed a higher Cd level (0.04± 0.002 mg L-1, P>0.05) than that of the permissible level whereas Rideemaliyadda (0.002± 0.002 mg L-1, P>0.05) shows lower levels than the permissible level. Lower- Rathkinda and Ginnoruwa areas showed higher levels of iron than that of the standard level of 0.3 mg L-1. Due to the high content of Cd levels in all the water samples, the water sources are at a risky status for drinking purpose even though the other parameters showed safe levels. en_US
dc.language.iso en en_US
dc.publisher Uva Wellassa University of Sri Lanka en_US
dc.subject Environmental Science en_US
dc.subject Environmental Engineering en_US
dc.subject Geochemistry en_US
dc.subject Ecology en_US
dc.title Assessment of Quality of Drinking Water in Selected Areas of Badulla District: An Approach to Causative Factors for Chronic Kidney Disease of Unknown Etiology (CKDu) en_US
dc.title.alternative International Research Conference 2019 en_US
dc.type Other en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search UWU eRepository


Browse

My Account